PSA NITROGEN GENERATOR

Nitrogen, with the chemical formula N2, is generally a colorless and odorless gas, and generally nitrogen is less dense than air. Nitrogen accounts for 78.08% (volume fraction) of the total atmosphere and is one of the main components of air. At standard atmospheric pressure, when nitrogen is cooled to -195.8 ° C, it becomes a colorless liquid, and when cooled to -209.8 ° C, liquid nitrogen becomes a snowy solid. Nitrogen is chemically inert and difficult to react with other substances at room temperature, so it is often used as preservatives. However, under high temperature and high energy conditions, it can undergo chemical changes with certain substances to prepare new substances useful to humans.

Main Spesification
Nitrogen Flow
0.5 ~ 1000 M³/h
Nitrogen Purity
98 ~ 99,999%
Nitrogen Pressure
1 ~ 6 Bar ( Adjustable )
Atmosphere Dew Point
-40°C ~ -70°C

Note : Due to the limited volume of the modular nitrogen generator, when the nitrogen flow is less than or equal to 50Nm3 / H-99.99%, the modular nitrogen generator is recommended;When the nitrogen flow rate is greater than 50Nm3 / H-99.99%, twin-tower nitrogen generator is recommended.

Different Models of Nitrogen Generator Parameter
Nitrogen Flow
0.5 ~ 160 M³/h
Working Temperature
5 ~ 40°C
Min. Inlet Pressure
6 Bar
Nitrogen Purity
99 ~ 99,999%
Noise
< 70dB
PDP
-40°C ~ -70°C
Power Supply
220V 50Hz/AC110V DC24V
Nitrogen Outler Pressure
1 ~ 7 Bar ( Adjustable )
Max. Ambient Temp.
≤ 45°C
Control Method
PLC programmable control
HMI microcomputer controller

Note : Other standards can be customized

Model
F
Purity 98 %
Z
Purity 99 %
S
Purity 99,5 %
H
Purity 99,9 %
Q
Purity 99,99 %
X
Purity 99,999 %

Technical Specification :

NGF Series = 98% Purity

Model Flow Rate (M³/Hr) Air Consumption (M³/Min) Adsorption Pressure (Bar) Air Inlet Nitrogen Outlet Weight (Kg) Dimension (mm) Diameter x Length x Height
NGF - 010 M
10
0,3
7
G 1⁄2
G 1⁄2
100
500
600
1750
NGF - 020 M
20
0,5
7
G 1⁄2
G 1⁄2
160
500
780
1750
NGF - 030 M
30
0,85
7
G 1⁄2
G 1⁄2
220
500
960
1750
NGF - 040 M
40
1,2
7
G 1⁄2
G 1⁄2
280
500
1140
1750
NGF - 050 M
50
1,5
7
G 3⁄4
G 3⁄4
340
500
1320
1750
NGF - 060 M
60
1,85
7
G 3⁄4
G 3⁄4
400
500
1480
1750
NGF - 070 M
70
2
7
G 3⁄4
G 3⁄4
460
500
1660
1750
NGF - 080 M
80
2,5
7
G 3⁄4
G 3⁄4
520
500
1840
1750
NGF - 100 M
90
3
7
G 1
G 1
800
830
1320
1750
NGF - 120 M
120
3,8
7
G 1
G 1
1000
830
1480
1750
NGF - 140 M
140
4,5
7
G 1
G 1
1200
830
1660
1750
NGF - 140 M
160
5
7
G 1
G 1
1350
830
1840
1750

Technical Specification :

NGZ Series = 99% Purity

Model Flow Rate (M³/Hr) Air Consumption (M³/Min) Adsorption Pressure (Bar) Air Inlet Nitrogen Outlet Weight (Kg) Dimension (mm) Diameter x Length x Height
NGZ - 005 M
5
0,3
7
G 1⁄2
G 1⁄2
100
500
600
1750
NGZ - 015 M
15
0,5
7
G 1⁄2
G 1⁄2
160
500
780
1750
NGZ - 025 M
25
0,85
7
G 1⁄2
G 1⁄2
220
500
960
1750
NGZ - 035 M
35
1,2
7
G 1⁄2
G 1⁄2
280
500
1140
1750
NGZ - 045 M
45
1,5
7
G 3⁄4
G 3⁄4
340
500
1320
1750
NGZ - 055 M
55
1,85
7
G 3⁄4
G 3⁄4
400
500
1480
1750
NGZ - 060 M
60
2
7
G 3⁄4
G 3⁄4
460
500
1660
1750
NGZ - 070 M
70
2,5
7
G 3⁄4
G 3⁄4
520
500
1840
1750
NGZ - 090 M
90
3
7
G 1
G 1
800
830
1320
1750
NGZ - 110 M
110
3,8
7
G 1
G 1
1000
830
1480
1750
NGZ - 130 M
130
4,5
7
G 1
G 1
1200
830
1660
1750
NGZ - 150 M
150
5
7
G 1
G 1
1350
830
1840
1750

Technical Specification :

NGS Series = 99,5% Purity

Model Flow Rate (M³/Hr) Air Consumption (M³/Min) Adsorption Pressure (Bar) Air Inlet Nitrogen Outlet Weight (Kg) Dimension (mm) Diameter x Length x Height
NGS - 005 M
5
0,3
7
G 1⁄2
G 1⁄2
100
500
600
1750
NGS - 015 M
15
0,5
7
G 1⁄2
G 1⁄2
160
500
780
1750
NGS - 020 M
20
0,85
7
G 1⁄2
G 1⁄2
220
500
960
1750
NGS - 025 M
25
1,2
7
G 1⁄2
G 1⁄2
280
500
1140
1750
NGS - 035 M
35
1,5
7
G 3⁄4
G 3⁄4
340
500
1320
1750
NGS - 045 M
45
1,85
7
G 3⁄4
G 3⁄4
400
500
1480
1750
NGS - 050 M
50
2
7
G 3⁄4
G 3⁄4
460
500
1660
1750
NGS - 060 M
60
2,5
7
G 3⁄4
G 3⁄4
520
500
1840
1750
NGS - 070 M
70
3
7
G 1
G 1
800
830
1320
1750
NGS - 090 M
90
3,8
7
G 1
G 1
1000
830
1480
1750
NGS - 100 M
100
4,5
7
G 1
G 1
1200
830
1660
1750
NGS - 120 M
120
5
7
G 1
G 1
1350
830
1840
1750

Technical Specification :

NGH Series = 99,99% Purity

Model Flow Rate (M³/Hr) Air Consumption (M³/Min) Adsorption Pressure (Bar) Air Inlet Nitrogen Outlet Weight (Kg) Dimension (mm) Diameter x Length x Height
NGH - 002 M
2
0,3
7
G 1⁄2
G 1⁄2
100
500
600
1750
NGH - 005 M
5
0,5
7
G 1⁄2
G 1⁄2
160
500
780
1750
NGH - 010 M
10
1,2
7
G 1⁄2
G 1⁄2
280
500
1140
1750
NGH - 015 M
15
1,5
7
G 3⁄4
G 3⁄4
340
500
1320
1750
NGH - 020 M
20
2
7
G 3⁄4
G 3⁄4
460
500
1660
1750
NGH - 025 M
25
2,5
7
G 3⁄4
G 3⁄4
520
500
1840
1750
NGH - 030 M
30
3
7
G 1
G 1
800
830
1320
1750
NGH - 035 M
35
3,5
7
G 1
G 1
1000
830
1480
1750
NGH - 040 M
40
4
7
G 1
G 1
1200
830
1660
1750
NGH - 050 M
50
4,5
7
G 1
G 1
1350
830
1840
1750

Technical Specification :

NGQ Series = 99,9% Purity

Model Flow Rate (M³/Hr) Air Consumption (M³/Min) Adsorption Pressure (Bar) Air Inlet Nitrogen Outlet Weight (Kg) Dimension (mm) Diameter x Length x Height
NGQ - 005 M
5
0,3
7
G 1⁄2
G 1⁄2
100
500
600
1750
NGQ - 010 M
10
0,5
7
G 1⁄2
G 1⁄2
160
500
780
1750
NGQ - 015 M
15
0,85
7
G 1⁄2
G 1⁄2
220
500
960
1750
NGQ - 020 M
20
1,2
7
G 1⁄2
G 1⁄2
280
500
1140
1750
NGQ - 025 M
25
1,5
7
G 3⁄4
G 3⁄4
340
500
1320
1750
NGQ - 030 M
30
1,85
7
G 3⁄4
G 3⁄4
400
500
1480
1750
NGQ - 035 M
35
2
7
G 3⁄4
G 3⁄4
460
500
1660
1750
NGQ - 040 M
40
2,5
7
G 3⁄4
G 3⁄4
520
500
1840
1750
NGQ - 050 M
50
3
7
G 1
G 1
800
830
1320
1750
NGQ - 060 M
60
3,8
7
G 1
G 1
1000
830
1480
1750
NGQ - 070 M
70
4,5
7
G 1
G 1
1200
830
1660
1750
NGQ - 080 M
80
5
7
G 1
G 1
1350
830
1840
1750

Technical Specification :

NGX Series = 99,999% Purity

Model Flow Rate (M³/Hr) Air Consumption (M³/Min) Adsorption Pressure (Bar) Air Inlet Nitrogen Outlet Weight (Kg) Dimension (mm) Diameter x Length x Height
NGX - 002 M
2
0,3
7
G 1⁄2
G 1⁄2
100
500
600
1750
NGX - 005 M
5
0,5
7
G 1⁄2
G 1⁄2
220
500
960
1750
NGX - 010 M
10
1,2
7
G 1⁄2
G 1⁄2
280
500
1140
1750
NGX - 015 M
15
1,5
7
G 3⁄4
G 3⁄4
400
500
1480
1750
NGX - 020 M
20
2,5
7
G 3⁄4
G 3⁄4
520
500
1840
1750
NGX - 025 M
25
3
7
G 1
G 1
800
830
1320
1750
NGX - 030 M
30
3,5
7
G 1
G 1
1000
830
1480
1750
NGX - 035 M
35
4
7
G 1
G 1
1200
830
1660
1750
NGX - 045 M
45
4,5
7
G 1
G 1
1350
830
1840
1750

Remarks :
– The front stage is equipped with a refrigerated dryer, the air compressor flow would be enlarged by 10%, the nitrogen dew point is below -30°C;
– The front stage is equipped with a refrigerated dryer + adsorption dryer, the air compressor flow would be enlarged by 20%, and the nitrogen dew point is
below -40°C;
– The front stage is equipped with a refrigerated dryer + adsorption dryer which tow models larger. Under the corresponding flow of the air compressor, the nitrogen dew point is below -50~-60°C.